This tutorial will walk the user running the DIAGNO code for a VMEC free boundary equilibrium. It is assumed the user has a converged free boundary equilibrium (wout file).


1. __The diagnostic files.__ > Each type of diagnostic requires a diagnostic definition file. For this case we will be using the NCSX flux loops as our diagnostic (). This file contains the specification of the 205 saddle type flux loops on NCSX. Below is a sample from this file.

205
   301     0     0   1_AA_1
-1.727866496 -0.196865519 -0.244078684
-1.728458951 -0.195219041 -0.243707768
-1.729057223 -0.193576931 -0.243331111
-1.729661666 -0.191939266 -0.242948435
-1.730272663 -0.190306020 -0.242559383
-1.730890620 -0.188677245 -0.242163625
-1.731515943 -0.187052941 -0.241760781
-1.732150765 -0.185434148 -0.241348743
-1.732794604 -0.183820791 -0.240927992
-1.733444869 -0.182211574 -0.240501170
-1.734099808 -0.180605506 -0.240070005
-1.734758303 -0.179001877 -0.239635716
-1.735419542 -0.177400077 -0.239199141
-1.736091626 -0.175803306 -0.238752278
-1.736766935 -0.174210624 -0.238302470
-1.737441940 -0.172618679 -0.237853474
-1.738116691 -0.171026557 -0.237405342
-1.738791214 -0.169433875 -0.236958149
-1.739465584 -0.167840482 -0.236511948
-1.740139852 -0.166246454 -0.236066584
-1.740814222 -0.164652249 -0.235621932
-1.741488440 -0.163057789 -0.235178219
-1.742162378 -0.161462872 -0.234735649
-1.742835986 -0.159867524 -0.234294299
-1.743509162 -0.158271591 -0.233854244
-1.744181907 -0.156675049 -0.233415611
-1.744854194 -0.155077897 -0.232978350
-1.745526075 -0.153480160 -0.232542512
-1.746197549 -0.151881891 -0.232108019

2. __Add the DIAGNO_IN name list to the input file__ > The DIAGNO code looks for the 'DIAGNO_IN' namelist in the VMEC input file (). The 'DIAGNO_IN' namelist is shown below

&diagno_in
  NU = 96
  NV = 48
  UNITS = 1.
  FLUX_DIAG_FILE = 'diagno_fluxloops.NCSX'
  INT_TYPE = 'simpson'
  INT_STEP = 2
  LRPHIZ = .false.
/

3 __Run DIAGNO__ > The DIAGNO code takes the VMEC input extension from the command line as so

 > ~/bin/xdiagno -vmec ncsx_c09r00_free
===========================================
=========  D I A G N O  (v.3.10)  =========
 - Reading input file
 - Reading equilibrium surface
  NZETA= 48  NOT EQUAL TO NP0B= 36  IN MGRID FILE
----- Virtual Casing Information -----
   INTEGRAL TYPE: Surface Current
   MIN_GRID_DISTANCE = 8.2976E-02
   NR =    1;   NU =   96;  NV =   48;  NFP =   3
   NUVP =  13824
   ABS_TOL = 1.0000E-05;   REL_TOL = 1.0000E-02
   R       = [   1.02284,   1.77827] [m]
   Z       =   0.64091[m]
   Beta    =   0.04086
   Current =-178.65318[kA]
   Flux    =   0.49707[Wb]
   VMEC v.   8.47
  - Calculating diagnostic responses
  --Calculating Fluxloop Values
     Loop         nseg                  flux
       1            301             -0.26122745E-04
       2            301             -0.20414744E-03
       3            301             -0.23783593E-03
       4            301             -0.20157644E-03
       5            301              0.22268368E-03
       6            301             -0.15810012E-03

4. __Examine the Output__ > The DIAGNO code will produce a diagno_flux.NCSX_c09r00_free file which contains the flux loop values and names.